        Recycled plastic recycling is the production of plastic that has been used new or discarded plastic through the dowel rod machine, and then through the granulator cut into granules of a kind of plastic pellets. The plastic recycling process mainly produces plastic washing, separation and wet crushing processes. The concentration of pollutants in the wastewater is closely related to the nature of the waste plastics used in its production. For the cleaning and crushing processes have high requirements on the suspended solids (SS) content in the water, you can use the VMC Ranmera precipitation + air flotation system as the main treatment process to remove most of the suspended solids in the wastewater, and then reuse the wastewater in the production process, to achieve the purpose of reducing the amount of wastewater discharged.

        Process flow diagram

        Equipment list

        Capacity 5-75m3/h

        Name 

        Basic system

        Quantity

        Upgrade system

        Quantity

        Full system

        Quantity

        System description

        Reaction system

        Feeding pump

        1 unit

        Feeding pump

        1 unit

        Feeding pump

        2 units

        The reaction system mainly doses right chemicals such as coagulants and coagulants to the sludge to induce flocculation of the sludge particles and improve their dewatering properties.

        Pipeline mixers

        2 pieces

        MR reaction cell

        1 set

        MR reaction cell

        1 set

        PAM dosing drum

        1 piece

        PAM dosing drum

        2 pieces

        PAM integrated dosing device

        1 set

        PAM dosing pump

        2 unit

        PAM dosing pump

        2 unit

        PAM dosing pump

        4 units

        PAC dosing drum

        1 piece

        PAC dosing drum

        2 pieces

        PAC dosing drum

        2 pieces

        PAC dosing pump

        2 unit

        PAC dosing pump

        2 unit

        PAC dosing pump

        4 units

        Flowmeter

        /

        Flowmeter

        /

        Flowmeter

        1 piece

        Sedimentation system

        VMC

        1 unit

        VMC

        1 unit

        VMC

        1 unit

        The sedimentation system is mainly for thickening the effluent and facilitating filter presses.

        Pneumatic Drainage Valve

        1 piece

        Pneumatic Drainage Valve

        1 piece

        Pneumatic Drainage Valve

        1 piece

        Mud pump

        1 unit

        Mud pump

        1 unit

        Mud pump

        2 units

        Flotation system

        Air flotation machine

        1 unit

        Air flotation machine

        1 unit

        Air flotation machine

        1 unit

        The air flotation system mainly uses some small bubbles generated in the water to achieve the purpose of removing some impurities.

        Pneumatic Drainage Valve

        1 piece

        Pneumatic Drainage Valve

        1 piece

        Pneumatic Drainage Valve

        1 piece

        Water reuse system

        Water collection tanks

        1 piece

        Water collection tanks

        1 piece

        Water collection tanks

        1 piece

        The water collection system is mainly to reuse the supernatant after concentration to reduce cost and save money.

        Drainage pump

        1 unit

        Drainage pump

        1 unit

        Drainage pump

        2 units

        Filtration system

        Mixing tanks

        1 piece

        Mixing tanks

        1 piece

        Mixing tanks

        1 piece

        The main function of the filter press system is solid-liquid separation

        Feeding pump

        1 unit

        Feeding pump

        1 unit

        Feeding pump

        2 units

        KMP Filter Press

        1 set

        KMP Filter Press

        1 set

        KMP Filter Press

        1 set

        Control system

        PLC control cabinet

        1 set

        PLC control cabinet

        1 set

        PLC control cabinet

        1 set

        The automation control of all our equipment will be integrated into this system and run fully automatically.

        Accessaries

        Pipes, valves, cables, etc.

        1 batch

        Pipes, valves, cables, etc.

        1 batch

        Pipes, valves, cables, etc.

        1 batch

        Cables and pipe and valve fittings required within the system, depending on the customer's site.

        Please request a detailed list of system from our sales consultant.


        Function comparison

        Function

        Basic system

        Senior system

        Full system

        Fully automated control

        Faulty alarm

        Automatic reaction vessels

        -

        Automatic standby switchover

        -

        -

        Automatic dosage adjustment

        -

        -

        Inverter control or not

        -

        -

        Time between infusions

        4 hours

        8 hours

        Fully automatic


        Optional features

        Serial number

        Name

        Specifications

        Function

        1

        Special anti-corrosion

        FRP Coating for the liquid connection parts

        Prevents corrosion from high acids, salts, fluorine, etc.

        2

        Special materials

        304/316L etc.

        According to the user's material characteristics

        3

        Skid mounted

        Patterned steel platform + fixed bracket + wire channel, piping, cables, etc.

        Easy to install, transport and flexible to move

        4

        PH automatic adjustment

        PH online monitoring + integrated control + acid and alkali dosing system

        Enables the effluent water to reach the standard PH value.

        5

        Precision filters

        Containing multistage centrifugal pumps

        Reducing the suspended solids content of filtrate and regulating water quality

        6

        Flameproof

        DIIBT4/CT4 etc.

        Electrical components, motors, etc. placed in explosion-proof areas are classified according to different levels.

        7

        Conveyor systems/staging systems

        Conveyor / Hopper

        Mud cake can be collected by conveying equipment or staging systems, reducing labour.